<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>AlbaCombi Analog to NMEA2000 Converter</title>
	<atom:link href="https://www.albacombi.com/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.albacombi.com/</link>
	<description></description>
	<lastBuildDate>Tue, 24 Jan 2023 14:48:33 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://i0.wp.com/www.albacombi.com/wp-content/uploads/2013/05/cropped-download.png?fit=32%2C32&#038;ssl=1</url>
	<title>AlbaCombi Analog to NMEA2000 Converter</title>
	<link>https://www.albacombi.com/</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">215710551</site>	<item>
		<title>Updated AlbaCombi Manual Guide</title>
		<link>https://www.albacombi.com/blog/albacombi-manual-guide/</link>
		
		<dc:creator><![CDATA[EMMI]]></dc:creator>
		<pubDate>Tue, 24 Jan 2023 14:48:31 +0000</pubDate>
				<category><![CDATA[AlbaCombi Configuration]]></category>
		<guid isPermaLink="false">https://www.albacombi.com/?p=3815</guid>

					<description><![CDATA[<p>Please download the new user manual guide for the AlbaCombi unit We have updated the AlbaCombi manual taking into account the main doubts that customers indicated to us. We hope...</p>
<p>The post <a href="https://www.albacombi.com/blog/albacombi-manual-guide/">Updated AlbaCombi Manual Guide</a> appeared first on <a href="https://www.albacombi.com">AlbaCombi Analog to NMEA2000 Converter</a>.</p>
]]></description>
		
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">3815</post-id>	</item>
		<item>
		<title>Basic Diagram Connection keeping old Gauges and senders</title>
		<link>https://www.albacombi.com/blog/basic-diagram-connection-keeping-old-gauges-and-senders/</link>
		
		<dc:creator><![CDATA[EMMI]]></dc:creator>
		<pubDate>Tue, 18 May 2021 15:03:19 +0000</pubDate>
				<category><![CDATA[AlbaCombi Configuration]]></category>
		<guid isPermaLink="false">https://www.albacombi.com/?p=3640</guid>

					<description><![CDATA[<p>We attach a basic diagram connection with some old VDO analog gauges with their senders, an MFD, and your computer. Remember to look for the IP Address in your browser....</p>
<p>The post <a href="https://www.albacombi.com/blog/basic-diagram-connection-keeping-old-gauges-and-senders/">Basic Diagram Connection keeping old Gauges and senders</a> appeared first on <a href="https://www.albacombi.com">AlbaCombi Analog to NMEA2000 Converter</a>.</p>
]]></description>
		
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">3640</post-id>	</item>
		<item>
		<title>Open Collector Relays to AlbaCombi</title>
		<link>https://www.albacombi.com/blog/open-collector-relays-to-albacombi/</link>
		
		<dc:creator><![CDATA[EMMI]]></dc:creator>
		<pubDate>Tue, 04 May 2021 10:48:02 +0000</pubDate>
				<category><![CDATA[AlbaCombi Configuration]]></category>
		<category><![CDATA[Configuration]]></category>
		<guid isPermaLink="false">https://www.albacombi.com/?p=3633</guid>

					<description><![CDATA[<p>AlbaCombi is able to manage two open collector relays. The max current of the open collector must be 25mA. Therefore, it should only be used with &#8220;low power&#8221; relays. If...</p>
<p>The post <a href="https://www.albacombi.com/blog/open-collector-relays-to-albacombi/">Open Collector Relays to AlbaCombi</a> appeared first on <a href="https://www.albacombi.com">AlbaCombi Analog to NMEA2000 Converter</a>.</p>
]]></description>
		
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">3633</post-id>	</item>
		<item>
		<title>AlbaCombi Web-based Interface</title>
		<link>https://www.albacombi.com/blog/albacombi-interface/</link>
		
		<dc:creator><![CDATA[EMMI]]></dc:creator>
		<pubDate>Tue, 27 Apr 2021 15:18:31 +0000</pubDate>
				<category><![CDATA[AlbaCombi Configuration]]></category>
		<category><![CDATA[Interface]]></category>
		<guid isPermaLink="false">https://www.albacombi.com/?p=3583</guid>

					<description><![CDATA[<p>In this post, we want to show you the main parts of the web-based interface of the AlbaCombi. First of all, you need to power your AlbaCombi. You can do...</p>
<p>The post <a href="https://www.albacombi.com/blog/albacombi-interface/">AlbaCombi Web-based Interface</a> appeared first on <a href="https://www.albacombi.com">AlbaCombi Analog to NMEA2000 Converter</a>.</p>
]]></description>
		
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">3583</post-id>	</item>
		<item>
		<title>Recover AlbaCombi after Firmware Update in Chrome</title>
		<link>https://www.albacombi.com/blog/recover-albacombi-after-firmware-update/</link>
		
		<dc:creator><![CDATA[EMMI]]></dc:creator>
		<pubDate>Wed, 24 Jun 2020 12:04:28 +0000</pubDate>
				<category><![CDATA[AlbaCombi Configuration]]></category>
		<category><![CDATA[Firmware]]></category>
		<guid isPermaLink="false">https://www.albacombi.com/?p=3225</guid>

					<description><![CDATA[<p>Guide to recover AlbaCombi You AlbaCombi has got crashed after trying to updating? This can be solved easily and we explain here how to do that&#8230; We have detected some...</p>
<p>The post <a href="https://www.albacombi.com/blog/recover-albacombi-after-firmware-update/">Recover AlbaCombi after Firmware Update in Chrome</a> appeared first on <a href="https://www.albacombi.com">AlbaCombi Analog to NMEA2000 Converter</a>.</p>
]]></description>
		
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">3225</post-id>	</item>
		<item>
		<title>Resistive or Voltage Measurement AlbaCombi Configuration</title>
		<link>https://www.albacombi.com/blog/resistance-or-voltage-config/</link>
		
		<dc:creator><![CDATA[EMMI]]></dc:creator>
		<pubDate>Fri, 06 Mar 2020 13:37:36 +0000</pubDate>
				<category><![CDATA[AlbaCombi Configuration]]></category>
		<category><![CDATA[Configuration]]></category>
		<guid isPermaLink="false">https://www.albacombi.com/?p=3206</guid>

					<description><![CDATA[<p>How to configure Resistive or Voltage mode in your AlbaCombi? With the AlbaCombi you can configure its measurement as Resistance or Voltage mode. The operation is as simple as removing...</p>
<p>The post <a href="https://www.albacombi.com/blog/resistance-or-voltage-config/">Resistive or Voltage Measurement AlbaCombi Configuration</a> appeared first on <a href="https://www.albacombi.com">AlbaCombi Analog to NMEA2000 Converter</a>.</p>
]]></description>
		
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">3206</post-id>	</item>
		<item>
		<title>Configuring Tanks in Albacombi to NMEA2000 Network</title>
		<link>https://www.albacombi.com/blog/nmea2000-configuration-tanks/</link>
		
		<dc:creator><![CDATA[Salvador Ferrairo]]></dc:creator>
		<pubDate>Wed, 22 Mar 2017 17:19:32 +0000</pubDate>
				<category><![CDATA[AlbaCombi Configuration]]></category>
		<category><![CDATA[Configuration]]></category>
		<guid isPermaLink="false">https://www.albacombi.com/?p=2990</guid>

					<description><![CDATA[<p>In the AlbaCombi you can use any of the 12 inputs to be converted into NMEA2000 tank information, the NMEA2000 bus just sends the percentage of tank and tank capacity...</p>
<p>The post <a href="https://www.albacombi.com/blog/nmea2000-configuration-tanks/">Configuring Tanks in Albacombi to NMEA2000 Network</a> appeared first on <a href="https://www.albacombi.com">AlbaCombi Analog to NMEA2000 Converter</a>.</p>
]]></description>
		
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2990</post-id>	</item>
		<item>
		<title>Update the AlbaCombi firmware</title>
		<link>https://www.albacombi.com/blog/update-albacombi-firmware/</link>
		
		<dc:creator><![CDATA[Salvador Ferrairo]]></dc:creator>
		<pubDate>Sun, 22 Mar 2015 16:59:03 +0000</pubDate>
				<category><![CDATA[AlbaCombi Configuration]]></category>
		<category><![CDATA[Firmware]]></category>
		<guid isPermaLink="false">https://www.albacombi.com/?p=2986</guid>

					<description><![CDATA[<p>In case you need to update AlbaCombi to the latest version or you want to reset your unit to factory configuration you need to update the firmware of the unit....</p>
<p>The post <a href="https://www.albacombi.com/blog/update-albacombi-firmware/">Update the AlbaCombi firmware</a> appeared first on <a href="https://www.albacombi.com">AlbaCombi Analog to NMEA2000 Converter</a>.</p>
]]></description>
		
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2986</post-id>	</item>
		<item>
		<title>Weird sensors, how to manage them with the AlbaCombi</title>
		<link>https://www.albacombi.com/blog/weird-sensors-how-to-manage-them-with-the-alba-combi/</link>
		
		<dc:creator><![CDATA[EMMI]]></dc:creator>
		<pubDate>Sun, 22 Feb 2015 20:54:11 +0000</pubDate>
				<category><![CDATA[AlbaCombi Configuration]]></category>
		<category><![CDATA[Configuration]]></category>
		<guid isPermaLink="false">https://www.albacombi.com/?p=2844</guid>

					<description><![CDATA[<p>In the world of analog sensors, you may find dozens of sensors, some of them may be difficult to interface to preconfigured analog to NMEA2000 converters. With the AlbaCombi you...</p>
<p>The post <a href="https://www.albacombi.com/blog/weird-sensors-how-to-manage-them-with-the-alba-combi/">Weird sensors, how to manage them with the AlbaCombi</a> appeared first on <a href="https://www.albacombi.com">AlbaCombi Analog to NMEA2000 Converter</a>.</p>
]]></description>
		
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2844</post-id>	</item>
		<item>
		<title>Configuring Batteries in AlbaCombi</title>
		<link>https://www.albacombi.com/blog/battery-configuration-in-alba-combi/</link>
		
		<dc:creator><![CDATA[EMMI]]></dc:creator>
		<pubDate>Sun, 15 Feb 2015 19:42:46 +0000</pubDate>
				<category><![CDATA[AlbaCombi Configuration]]></category>
		<category><![CDATA[Configuration]]></category>
		<guid isPermaLink="false">https://www.albacombi.com/?p=2838</guid>

					<description><![CDATA[<p>In the Alba Combi you can set two types of batteries, the ones associated with the engine PGN often referred as &#8220;alternator&#8221; in within the PGN or as a full...</p>
<p>The post <a href="https://www.albacombi.com/blog/battery-configuration-in-alba-combi/">Configuring Batteries in AlbaCombi</a> appeared first on <a href="https://www.albacombi.com">AlbaCombi Analog to NMEA2000 Converter</a>.</p>
]]></description>
		
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2838</post-id>	</item>
	</channel>
</rss>
